Device for Connection of Luminaires

DCL
Type Ceiling lamp connector
Production history
Designer IEC
Designed 2005 (2005)
Manufacturer Elko, Legrand, Schneider Electric, Lébénoïd, more
General specifications
Length 24.2 mm + length of pins
Width 30.2 mm
Audio signal None
Video signal None
Cable Electrical
Pins 3
Connector DCL
Electrical
Signal 6 ampere
Earth Yes
Max. voltage 250 V AC
Max. current 6 A
Data
Data signal None
Pinout
Pin 1 Load L
Pin 2 Protective earth PE
Pin 3 Neutral N
3 on the plug, 6 inside the socket.

Device for Connection of Luminaires (DCL) is a European standard for ceiling light fixtures introduced in 2005 and refined in 2009. It uses 6 ampere. DCL must carry the CE marking as per the Low Voltage Directive. DCL is only allowed to be installed with ground.

Example of DCL socket.
Plug (external)
PinColorFunction
1Load (L)
2Protective earth
3Neutral (N)
Socket internals
PinColorFunction
1Load (L)
2Load (L)
3Protective earth
4Protective earth
5Neutral (N)
6Neutral (N)

Adoption

Country Notes
Austria
Belgium
Bulgaria
Croatia
Cyprus
Czech Republic
Denmark
Estonia
Finland
France Mandatory in new and renovated homes since 2001. Norme Française NF C 15-100.
Germany
Greece
Hungary
Republic of Ireland
Italy
Latvia
Lithuania
Luxembourg
Malta
Netherlands
Poland
Portugal
Romania
Slovakia
Slovenia
Spain
Sweden Mandatory since April 1, 2019
Non-EU countries
Country Notes
Norway Mandatory since December 31, 2010
UK Not mandatory, but recommended by the IET Wiring Regulations.